banner_wyszukiwarka(4).jpg

SFA condensate pump SANICONDENS Clim Classic

The Symbol : 11012464931

SFA condensate pump SANICONDENS Clim Classic The condensate pump for air conditioning is supplied with all mounting accessories and connectors that allow very easy installation. The device consists of two basic components: the takeover block and the pump block.

The Availability Of : Duża dostępność

: 249.00

: 249.00

opak
Phone orde SMS: +48606376838

Shipping within : 24 hours
EAN :
3308815077574

SFA condensate pump SANICONDENS Clim Mini Classic

Small pump for installation inside the air conditioner

  • Very quiet operation of 21dB
  • Transparent control module
  • Installation inside the mounting strip

Sanicondens Clim Mini is a pump designed to drain condensate from air conditioning equipment. Its small size allows it to be used in a Multi-Split air conditioner (mounted on the wall).

The pump is supplied with all mounting accessories and connectors that allow for very easy installation. The device consists of two basic components: the takeover block and the pump block. The condensate first goes to the transfer block (located on the drip tray, up to 2 m away from the pump block). When the condensate level is high, the pump turns on and sucks it in to drain it. IP64 ingress protection, possibility of connecting an external alarm. The noise level is only 21 dB(A).

Technical data sheet SANICONDENS Clim Mini

  • diameter of entrances - 17 mm
  • pressure pipe diameter - 8-10 mm
  • Power supply - 220-240 V/50 Hz
  • Degree of protection - IP20
  • Sound level - 21 dB(A)
  • Horizontal pumping max -60 m
  • Vertical embossing - max 6 m
  • Max. capacity - 15 L/h
  • Motor power - 22 W
  • Max. temperature of inflowing condensate - 35°C
  • Connection options - air conditioners up to 8kW

Module dimensions:

 

The SANICONDENS Clim Mini is supplied with a flexible module connection tube (1.5m), a mounting bracket, a vent tube and a power cable.

Parameters :
Brand:
SFA
Energy efficiency class:
A+
Kod producenta:
445912
Packaging Condition:
oryginalne
Status:
New
Voltage / Power:
230V
Waga produktu z opakowaniem jednostkowym:
0.5 (3)

Safety Information

General safety rules for fittings, ducts, grilles and mounting accessories for ventilation

Elements of ventilation systems, such as fittings, ducts, ventilation grilles and mounting accessories, have been designed to ensure proper air circulation in buildings.
Correct installation and operation are crucial for the safety of users and the performance of the entire system.

Principles of safe use and installation

Installation by qualified persons only
All installation works should be carried out by people with experience in the installation of ventilation systems and knowledge of applicable standards.

Safe mounting location

Assemble components according to the design of the ventilation system.

Avoid placing wires and grilles near heat sources, open flames, or devices that emit heat.

Avoiding mechanical damage

Do not bend, deform, or damage the ducts and fittings during assembly.

In the event of visible mechanical damage, the element should not be used.

Protection against moisture and corrosion

Use the elements for their intended purpose – in rooms exposed to moisture, use fittings and ducts made of corrosion-resistant materials.

Store mounting accessories in dry and clean conditions.

Proper fixation and stabilization

All system components must be installed stably and in accordance with the manufacturer's instructions.

Improper fastening can lead to loose ductwork, reduced ventilation performance or structural damage.

Safety at work at height
When installing grilles or cables under the ceiling, appropriate safety safeguards such as stable ladders, scaffolding and personal protective equipment must be used.

Potential risks

Falling of elements – resulting from improper fastening of wires, fittings or grilles.

Mechanical damage – caused by improper transport or assembly.

Risk of fire – the use of unsuitable materials in high-temperature areas can lead to damage and fire hazards.

Improper air quality – installation errors can limit proper air circulation and negatively affect the comfort of users.

Maintenance and inspections

Regularly check the condition of wires, fittings, grilles and mounting accessories.

Clean the vents of dust and debris to maintain system performance.

If damage is found, replace the components with new ones in accordance with the manufacturer's recommendations.

Summary

Proper installation and operation of fittings, ducts, grilles and ventilation accessories guarantee the safety of users, system efficiency and long service life of the installation.
Compliance with the above rules minimizes the risk of failure and ensures comfortable and safe air exchange in rooms.

Manufacturer details

SFA
Wojkowicka 14a
41-250 Czeladź
Poland

606376838
info@wentec.pl

There is currently no comments or ratings for this product.
Ask a question

Zobacz co o nas mówią klienci