banner_wyszukiwarka(4).jpg

Duct fan ICM-EC-315/2206M 2206m3/h

The Symbol : 92374

Duct fan ICM-EC-315/2206M 2206m3/h - quiet, economical, with EC motor, for supply/extraction. PP housing, ABS rotor, vertical/horizontal mounting, speed control, IP44.

The Availability Of : Średnia dostępność

: 898.00

: 898.00

opak
Phone orde SMS: +48606376838

Shipping within : 24 hours
EAN :
5905679892374

Duct fan ICM-EC-315/2206M 2206m3/h

Dedicated smooth surface-mounted speed controller for EC motors model HMTPadd to cart

Key features of the fan:

  • Energy-efficient - modern EC motors.

  • Infinitely adjustable 0-10V speed range.

  • Even more efficient

  • Special profiled handlebars

  • Dynamically balanced diagonal rotor.

The ICM EC duct fan is an innovative solution in the field of ventilation systems, characterized by outstanding efficiency and low energy consumption. Its diagonal design, which uses an advanced electronically commutated (EC) motor, ensures high performance with minimal noise. This design makes it an extremely environmentally friendly and economical device.

The fan housing is made of durable polypropylene, while the impeller is made of high-quality ABS plastic, which guarantees a long service life and reliability of the device. Thanks to special connectors, assembly, disassembly and maintenance of the fan are extremely easy and intuitive. In addition, the fan can be installed in both horizontal and vertical positions, making it an extremely versatile solution to suit a variety of user needs.

The fan's electric motor, equipped with integrated thermal protection, is powered by 230V ~1.50Hz. It is characterized by the ability to smoothly adjust the rotational speed in the entire range, while maintaining high efficiency. This regulation is carried out by means of a controller that uses an analog signal of 0-10V, which ensures precise adjustment of the operating parameters to individual needs. The IP44 rating guarantees safe use of the device in various conditions.

The ICM EC fan is adapted to the transport of unpolluted air, finding its application in both supply and exhaust systems of residential, public buildings, offices and shops. It can also be used in extractor hood systems, where grease filters are required to ensure optimum efficiency.

Capable of operating at temperatures up to 60 °C, the ICM EC fan is an extremely versatile unit, suitable for a wide range of applications, making it the ideal solution for those looking for an efficient and cost-effective ventilation system.

Fan Specifications:

тур Wydajność[m3/h] obroty[rpm] М oc[W] Intensity [А] Voltage [V] Frequency [Hz] Sound pressure [dB(A)] Mass (Кg]
IСМ-ЕС 100/366М 366 3800 70 0,47 230 50 35 1,80
IСМ-ЕС-125/561М 561 3800 70 0,47 230 50 35 2,00
ICM-EC-150-160/647M 647 3000 70 0,47 230 50 43 2,70
IСМ-ЕС-200/ 1250М 1250 3000 180 1,05 230 50 50 4,90
IСМ-ЕС-250/ 1652M 1652 3000 255 1,5 230 50 65 7,90
IСМ-ЕС-З15/2206М 2206 2350 250 1,40 230 50 68 11,30

Fan dimensions :

Parameters :
Brand:
Havaco
Colour:
white
Energy efficiency class:
A+
Hole diameter:
315 mm
Kind:
Channel
Material:
PCV
Status:
New

Safety Information

General Safety Rules for Mechanical Fans for Building Ventilation

Mechanical fans are a key component of mechanical ventilation systems in residential, commercial and industrial buildings. Their correct installation, operation and maintenance are crucial for the safety of users, the efficiency of the system and the durability of the device.

Principles of safe use and installation

Installation by qualified personnel only
A mechanical fan should be installed by persons with appropriate electrical qualifications and experience in the installation of mechanical ventilation systems.

Correct Mounting Location

The device should be installed in accordance with the installation design and manufacturer's documentation.

Keep a safe distance from heat sources, fire, gas installations and flammable materials.

Safe electrical connection

The electrical installation must be carried out in accordance with the applicable standards and manufacturer's requirements.

The fan should be connected to a properly protected electrical circuit with proper grounding.

Any service or installation work should be performed with the power supply disconnected.

Protection against moisture and dust

Use fans for their intended purpose – wet room models must have an appropriate IP rating.

Do not install fans where there is a risk of water damage, unless they have been designed to do so.

Proper fixation of the device

The device must be mounted stably to prevent vibration, noise and possible mechanical damage.

In the case of ceiling or roof fans, additional vibration protection must be used.

Ensuring free air flow

Do not obstruct fan inlets or outlets.

Regularly check the patency of the ventilation ducts to avoid overloading the motor.

Potential risks

Electric shock – resulting from improper connection, damaged wires or lack of grounding.

Engine overheating – caused by a lack of obstruction of ventilation ducts or a blockage of the rotor.

Risk of fire – when the fan is installed near flammable materials or in unsuitable environments.

Noise and vibration – incorrect installation can lead to excessive noise and damage to the building structure.

Decrease in air quality – an incorrectly selected fan can result in insufficient air exchange, which negatively affects the health of users.

Maintenance and inspections

Regularly clean the fan of dust, dust, and other debris to maintain its performance.

Check the condition of electrical cables, connections and the rotor.

Perform periodic technical inspections in accordance with the manufacturer's recommendations.

If abnormalities are detected, such as excessive noise, vibrations, burning smell or problems with the operation of the device – disconnect the power supply and contact an authorized service center.

Summary

Mechanical fans are reliable devices that ensure proper air circulation in buildings, but they require proper installation and operation.
Compliance with the above safety rules minimizes the risk of failure, increases the efficiency of the ventilation system and extends the life of the device.

Manufacturer details

Havaco
Działkowa 121A
02-234 Warszawa
Poland

606376838
info@wentec.pl

Reviews are not verified