banner_wyszukiwarka(4).jpg

HRU Komfovent Domekt R400V

The Symbol : 10501602361

Komfovent Domekt R400V recuperator with C6.1 panel Under normal operating conditions, the rotary heat exchanger does not freeze. Even at outside temperatures below -20°C, additional heating of the fresh air is not necessary, resulting in significant savings in thermal energy even in severe frosts. The use of a rotary heat exchanger reduces the energy consumption for heating the supply air by about four times.

The Availability Of : Duża dostępność

: 10900.00

: 10900.00

Inne modele:
opak
Phone orde SMS: +48606376838

Shipping within : 24 hours
EAN :
5904326322868

KOMFOVENT DOMEKT R 400V RECUPERATOR WITH C6.1 CONTROL PANEL WITH ROTARY HEAT EXCHANGER

Advantages of the Domekt R series

Heat energy saving In the process of room ventilation, the heat from the exhaust air is transferred to the supply air.

Efficient heating

Under normal operating conditions, the rotary heat exchanger does not freeze. Even at outside temperatures below -20°C, additional heating of the fresh air is not necessary, resulting in significant savings in thermal energy even in severe frosts. The use of a rotary heat exchanger reduces the energy consumption for heating the supply air by about four times.

Moisture balance in the air

Under normal operating conditions, there is no condensation on the rotary heat exchanger, as most of it is returned to the rooms. Excess moisture is drained to the outside. The air in the rooms does not dry out and the appropriate humidity is maintained. Since no condensate is formed, a condensate drain is also not needed, which simplifies the installation of the unit.

Low noise level

Domekt R air handling units are equipped with low-noise fans and soundproofing insulation, which ensure quiet operation of the units.

Advantages of rotary heat exchanger

  • High Efficiency
  • No freezing
  • Four times less energy consumption for heating the supplied air.
  • Transfer of moisture to the supplied air - the use of additional humidifiers in ventilated rooms is not necessary.
  • No condensate drain is needed - easy installation of the unit.
  • Possibility of cooling recovery, and therefore lower energy consumption for air cooling.

Efficiency: Rotary heat exchangers are offered in two efficiency levels. Standard, optimal efficiency is provided by the L-type heat exchanger, while higher efficiency coefficients are achieved by the XL type heat exchangers.

Specifications:

Maximum air flow (m3/h) 371
Maximum Air Flow (I/s) 103
Rated Air Flow (m3/s) 0,072
Rated Differential Pressure (Pa) 50
JPM (W/(m3/h)) 0,3
Temperature efficiency of heat recovery (%) 85
Electric heater power (kW) / At (oc) 1/11,3
Rated Voltage (V) 1-230
Maximum load current HE (A) 6,5
Power cord (mm2) 3><1.5
Power consumption of fan drive at maximum flow (W) 114
Power Consumption of Fan Drive at Rated Flow (W) 41
Sound power level, LWA, dB(A) 37
Sound pressure level, Lm, dB(A) (3 m) 27
Filter dimensions BxHxL (mm) 428x231x46
Unit Dimensions BxHxL (mm) 495x561x598
Required operating space (mm) 600
Weight (kg) 49

Dimensions:

IMPORTANT: PLEASE CONFIRM THE VERSION: LEFT OR RIGHT WHEN ORDERING

image
image
Parameters :
Brand:
Komfovent
Hole diameter:
160 mm
Packaging Condition:
oryginalne
Status:
New
Waga produktu z opakowaniem jednostkowym:
75

Safety Information

General safety rules for fittings, ducts, grilles and mounting accessories for ventilation

Elements of ventilation systems, such as fittings, ducts, ventilation grilles and mounting accessories, have been designed to ensure proper air circulation in buildings.
Correct installation and operation are crucial for the safety of users and the performance of the entire system.

Principles of safe use and installation

Installation by qualified persons only
All installation works should be carried out by people with experience in the installation of ventilation systems and knowledge of applicable standards.

Safe mounting location

Assemble components according to the design of the ventilation system.

Avoid placing wires and grilles near heat sources, open flames, or devices that emit heat.

Avoiding mechanical damage

Do not bend, deform, or damage the ducts and fittings during assembly.

In the event of visible mechanical damage, the element should not be used.

Protection against moisture and corrosion

Use the elements for their intended purpose – in rooms exposed to moisture, use fittings and ducts made of corrosion-resistant materials.

Store mounting accessories in dry and clean conditions.

Proper fixation and stabilization

All system components must be installed stably and in accordance with the manufacturer's instructions.

Improper fastening can lead to loose ductwork, reduced ventilation performance or structural damage.

Safety at work at height
When installing grilles or cables under the ceiling, appropriate safety safeguards such as stable ladders, scaffolding and personal protective equipment must be used.

Potential risks

Falling of elements – resulting from improper fastening of wires, fittings or grilles.

Mechanical damage – caused by improper transport or assembly.

Risk of fire – the use of unsuitable materials in high-temperature areas can lead to damage and fire hazards.

Improper air quality – installation errors can limit proper air circulation and negatively affect the comfort of users.

Maintenance and inspections

Regularly check the condition of wires, fittings, grilles and mounting accessories.

Clean the vents of dust and debris to maintain system performance.

If damage is found, replace the components with new ones in accordance with the manufacturer's recommendations.

Summary

Proper installation and operation of fittings, ducts, grilles and ventilation accessories guarantee the safety of users, system efficiency and long service life of the installation.
Compliance with the above rules minimizes the risk of failure and ensures comfortable and safe air exchange in rooms.

Manufacturer details

Komfovent
Działkowa 121A
02-232 Warszawa
Poland

606376838
info@wentec.pl

There is currently no comments or ratings for this product.
Ask a question

Zobacz co o nas mówią klienci