The optimal 600 Power recuperator is designed to exchange air (bring in fresh air from the outside and expel the used air from the rooms) with maximum thermal energy conservation (up to 95%), it can be used both in residential and public buildings

The Availability Of : Duża dostępność

: 7590.00

: 7590.00

opak
Phone orde SMS: +48606376838

Shipping within : 24 hours
EAN :
5901560510808

OPTIMAL 600 POWER recuperator air handling unit by Dospel

 

The OPTIMAL unit is equipped with a acoustically and thermally insulated housing, a heat exchanger, high-quality filters and an automatic by-pass, which allows the rooms to be cooled in the summer. When the bypass is opened, there is no heat transfer in the exchanger. Bypass is used for free cooling of ventilated rooms with the use of cool air, e.g. from GHE.

Together with the air handling unit, there is a controller with an ecoTOUCH PLUM touch panel. Changes to the regulator settings are made via the rotary menu system. It allows you to control the flow of streams, allowing for smooth adjustment of fan speeds and weekly programming. The recuperator is equipped with automatic frost protection and a condensate drainage system. The controller is supplied with a 20m long connecting cable terminated with Rj11 plugs.

The controller has built-in software modules that allow the recuperation unit to work with selected types of air quality sensors: digital carbon dioxide (CO2) level sensor, analog carbon dioxide (CO2) level sensor or analog humidity sensor. It is possible to connect to external ecoPRESS-01 differential pressure transmitters. The ecoNET300 additional Internet module enables remote management of the regulator's operation via Wi-Fi or LAN using the Internet service. The control panel has a cable terminated with a plug adapted to be connected directly to a single-phase socket with a PE wire. It should be connected to a 230V/50Hz electrical system with protective earthing.

A properly installed OPTIMAL recuperator does not require any special maintenance during its use. From time to time, it is necessary to carry out a preventive inspection of fans, drain port and diffusers. The device is equipped with a timed filter dirt indicator that counts down the time remaining until the next filter change. The filter cartridge made of polyester fabric cannot be cleaned and must be replaced with a new one if necessary. When changing the filter, reset the replacement meter. This is important for maintaining the efficiency of the control panel and maintaining high energy efficiency.

 

Specifications
Connection diameter 198 mm
Power Consumption Min. 17 W / Max 355 watts
Dimensions 838 x 625 x 583 mm
Air Output 940 m3/h (by-pass closed)
Supply voltage 230 V
Turnovers 1650 rpm
Protection IP 40
Insulation class 1
Bearing Type Rolling
Scales 50
Available pressure 0-450Pa
Pressure up to 53 dB(A) / lm

Dimensions of the recuperator:

 

image

Parameters :
Brand:
Dospel
Energy efficiency class:
A
Funkcje:
wentylacja
Packaging Condition:
oryginalne
Status:
New
Średnica otworu (mm):
200
Waga produktu z opakowaniem jednostkowym:
50

Safety Information

General safety rules for fittings, ducts, grilles and mounting accessories for ventilation

Elements of ventilation systems, such as fittings, ducts, ventilation grilles and mounting accessories, have been designed to ensure proper air circulation in buildings.
Correct installation and operation are crucial for the safety of users and the performance of the entire system.

Principles of safe use and installation

Installation by qualified persons only
All installation works should be carried out by people with experience in the installation of ventilation systems and knowledge of applicable standards.

Safe mounting location

Assemble components according to the design of the ventilation system.

Avoid placing wires and grilles near heat sources, open flames, or devices that emit heat.

Avoiding mechanical damage

Do not bend, deform, or damage the ducts and fittings during assembly.

In the event of visible mechanical damage, the element should not be used.

Protection against moisture and corrosion

Use the elements for their intended purpose – in rooms exposed to moisture, use fittings and ducts made of corrosion-resistant materials.

Store mounting accessories in dry and clean conditions.

Proper fixation and stabilization

All system components must be installed stably and in accordance with the manufacturer's instructions.

Improper fastening can lead to loose ductwork, reduced ventilation performance or structural damage.

Safety at work at height
When installing grilles or cables under the ceiling, appropriate safety safeguards such as stable ladders, scaffolding and personal protective equipment must be used.

Potential risks

Falling of elements – resulting from improper fastening of wires, fittings or grilles.

Mechanical damage – caused by improper transport or assembly.

Risk of fire – the use of unsuitable materials in high-temperature areas can lead to damage and fire hazards.

Improper air quality – installation errors can limit proper air circulation and negatively affect the comfort of users.

Maintenance and inspections

Regularly check the condition of wires, fittings, grilles and mounting accessories.

Clean the vents of dust and debris to maintain system performance.

If damage is found, replace the components with new ones in accordance with the manufacturer's recommendations.

Summary

Proper installation and operation of fittings, ducts, grilles and ventilation accessories guarantee the safety of users, system efficiency and long service life of the installation.
Compliance with the above rules minimizes the risk of failure and ensures comfortable and safe air exchange in rooms.

Manufacturer details

Dospel
Główna 188
42-280 Częstochowa
Poland

606376838
info@wentec.pl

There is currently no comments or ratings for this product.
Ask a question

Zobacz co o nas mówią klienci