banner_wyszukiwarka(4).jpg

Single-pipe decentralised recuperator AHR-160 52m3/h

The Symbol : 11236410206

AHR160 is a new generation of decentralised ventilation devices that allow ventilation of rooms while reducing heat loss. Thanks to the use of a ceramic accumulation exchanger, the AHR retains and stores thermal energy, and then heats cooler, supplied air from the outside. The difference between the AHR series and HRV lies in the solutions used to automate its work. The electronics used control the operation of the device and adjust its parameters depending on the conditions in the room in which the AHR was installed.

The Availability Of : Duża dostępność

: 1845.00

: 1845.00

opak
Phone orde SMS: +48606376838

Shipping within : 24 hours
EAN :
5905033302150

Single-pipe recuperator Awenta AHR160

 

AHR160 is a new generation of decentralised ventilation devices that enable ventilation of rooms while reducing heat loss. Thanks to the use of a ceramic accumulating heat exchanger, the AHR retains and stores heat energy in order to heat the cooler air supplied from the outside. The difference between the AHR series and the HRV series lies in the solutions used to automate its operation. The electronics used control the operation of the device and adjust its parameters depending on the conditions in the room where the AHR has been installed. 

The AHR160 single-tube decentralised recuperator has the ability to connect several devices installed in one or more rooms with the possibility of pairing them via wireless communication, without the need to connect the devices with a power cord. Pairing is possible in different modes, e.g. both units only supply or only exhaust and alternating operation: one unit supplies and the other exhausts.

The basic function of the AHR160 device is to ensure air exchange in the room, while reducing heat loss. The recovery of heat lost in the ventilation process is possible thanks to the use of a ceramic storage exchanger, which retains and stores heat energy to then heat the cooler air supplied from the outside. If the supply air has a higher temperature than the temperature in the room, the exchanger will lower  it using the temperature of the exhaust air.

The ceramic heat exchanger is the heart of the device and one of its most important elements. A hexagonal heat exchanger has been used in the AHR, thanks to which one of the highest heat recovery coefficients in decentralised ventilation devices available on the market has been obtained.

 

Operating parameters of the device in each 3 gears

image

Construction of the AHR160 recuperator

image




image

 

SUPPLY

The heat stored in the heat exchanger is collected by the supply air stream and then transferred to the room. After the exchanger cools down, the direction of operation is automatically changed. The optimal operating time in one direction is determined by temperature readings from sensors located upstream and downstream of the heat exchanger.

image

EXHAUST AIR

When operating in the exhaust direction, the heat is stored in a ceramic heat exchanger. When the heat exchanger is completely heated, the direction of operation is automatically changed.

The optimal operating time in one direction is determined by temperature readings from sensors located upstream and downstream of the heat exchanger.

image

 

Wireless

The Awenta AHR160 recuperator has the ability to connect several devices installed in one or more rooms with the possibility of pairing them via wireless communication. Without the hassle of connecting devices with a power cord. Pairing is possible in different modes, e.g. both units only supply or only exhaust and alternating operation : one unit supplies and the other exhausts.

image

 

The AHR160 is equipped with an IR remote control, which allows the device to be operated in the full range of changing operating modes, operating speed, as well as switching on and off.

image

image

Dimensions of the recuperator:

image

Parameters :
Brand:
Awenta
Colour:
biały (2)
Energy efficiency class:
A+
Kind:
rekuperator
Kod producenta:
3341990
Material:
PCV
Packaging Condition:
oryginalne
Status:
New
Sterowanie:
na pilot
Waga produktu z opakowaniem jednostkowym:
2 (3)

Safety Information

General safety rules for fittings, ducts, grilles and mounting accessories for ventilation

Elements of ventilation systems, such as fittings, ducts, ventilation grilles and mounting accessories, have been designed to ensure proper air circulation in buildings.
Correct installation and operation are crucial for the safety of users and the performance of the entire system.

Principles of safe use and installation

Installation by qualified persons only
All installation works should be carried out by people with experience in the installation of ventilation systems and knowledge of applicable standards.

Safe mounting location

Assemble components according to the design of the ventilation system.

Avoid placing wires and grilles near heat sources, open flames, or devices that emit heat.

Avoiding mechanical damage

Do not bend, deform, or damage the ducts and fittings during assembly.

In the event of visible mechanical damage, the element should not be used.

Protection against moisture and corrosion

Use the elements for their intended purpose – in rooms exposed to moisture, use fittings and ducts made of corrosion-resistant materials.

Store mounting accessories in dry and clean conditions.

Proper fixation and stabilization

All system components must be installed stably and in accordance with the manufacturer's instructions.

Improper fastening can lead to loose ductwork, reduced ventilation performance or structural damage.

Safety at work at height
When installing grilles or cables under the ceiling, appropriate safety safeguards such as stable ladders, scaffolding and personal protective equipment must be used.

Potential risks

Falling of elements – resulting from improper fastening of wires, fittings or grilles.

Mechanical damage – caused by improper transport or assembly.

Risk of fire – the use of unsuitable materials in high-temperature areas can lead to damage and fire hazards.

Improper air quality – installation errors can limit proper air circulation and negatively affect the comfort of users.

Maintenance and inspections

Regularly check the condition of wires, fittings, grilles and mounting accessories.

Clean the vents of dust and debris to maintain system performance.

If damage is found, replace the components with new ones in accordance with the manufacturer's recommendations.

Summary

Proper installation and operation of fittings, ducts, grilles and ventilation accessories guarantee the safety of users, system efficiency and long service life of the installation.
Compliance with the above rules minimizes the risk of failure and ensures comfortable and safe air exchange in rooms.

Reviews are not verified