FK150E3 air curtain 150cm 10kW 400V
The Symbol : 7211171539
Air curtain FK150E3 150cm/10kW/400V Air curtain with electric heater FK FIRMY FERONO
The Availability Of : Duża dostępność 997 opak
Price: 1769.00
Price: 1769.00
For free delivery are missing -,--
Sum NET 0,00 €
Sum Gross 0,00 €
Price includes discounts
For free delivery are missing -,--
Sum NET 0,00 €
Sum Gross 0,00 €
Price includes discounts

The Symbol : 7211171539
Air curtain FK150E3 150cm/10kW/400V Air curtain with electric heater FK FIRMY FERONO
The Availability Of : Duża dostępność 997 opak
Price: 1769.00
Price: 1769.00
The widest curtain of the FERONO series in three-phase version — 150 cm protection and performance 1900 m3/h for large entrances and gates
Air Curtain FERONO FK150E3 R15 creates an invisible air barrier that effectively separates the interior climate from the outside air. Mounted above the entrance reduces heat escape in winter and hot air in summer, reducing heating and air conditioning costs even with intense customer traffic. Highest in series performance 1900 m3/h and a stream of range to 3 meters protect wide entrances to markets, salons, hotels, warehouses and service facilities — with a light of up to 150 cm.
Energy efficient device 3,3 / 6,7 / 10,0 kW three-phase PTC heater with three degrees of heat, which instantly heats the air and automatically adjusts the power consumption to the temperature. Power 400 V the power distributes evenly into three phases, so the load of a single phase remains low even at a full 10 kW heating.


| FERONO FK150E3 R15 — Specification | |
|---|---|
| Model | FERONO FK150E3 R15 |
| Type | Air curtain with electric heater PTC |
| Heating power | 3.3 kW / 6.7 kW / 10.0 kW (three heating steps) |
| Power | 400 V / 50 Hz (3-phase) |
| Fan power | 230 W |
| Max. airflow | 1900 m3/h |
| Max. air speed | 11 m/s |
| Noise level | 57-59 dB(A) |
| Max. mounting height | 3 m |
| Width | 1500 mm |
| Height | 195 mm |
| Depth | 265 mm |
| Net / gross weight | 20.5 kg / 22.0 kg |
| Control | Wireless remote control, panel on the device, optional wall controller |
| Non-potential contact (Dry Contact) | Yes, built-in (On/Off) |
| Magnetic contactron | Yes, in the set |
| Distance from departure | Air speed |
|---|---|
| 0 m (output) | 11.0 m/s |
| 1 m | 7,0 m/s |
| 2 m | 4.5 m/s |
| 3 m | 3,0 m/s |
Curtain mounted horizontally, above the door opening, up to 3 m high from the floor. The width of the device (150 cm) shall be equal to or greater than the width of the protected opening — at the wider entrances of the curtain may be combined into a series. Device requires three-phase power supply 400 V; thanks to the distribution of power into three phases the load of a single phase remains low even at full heating power. The built-in touch of Dry Contact and the attached contactron allow you to work fully automatic — the curtain only starts with the door open, which further reduces operating costs.
Includes: air curtain FK150E3 R15, wireless remote control, magnetic contactor, mounting handles, instruction manual in Polish.
General safety rules for fittings, ducts, grilles and mounting accessories for ventilation
Elements of ventilation systems, such as fittings, ducts, ventilation grilles and mounting accessories, have been designed to ensure proper air circulation in buildings.
Correct installation and operation are crucial for the safety of users and the performance of the entire system.
Principles of safe use and installation
Installation by qualified persons only
All installation works should be carried out by people with experience in the installation of ventilation systems and knowledge of applicable standards.
Safe mounting location
Assemble components according to the design of the ventilation system.
Avoid placing wires and grilles near heat sources, open flames, or devices that emit heat.
Avoiding mechanical damage
Do not bend, deform, or damage the ducts and fittings during assembly.
In the event of visible mechanical damage, the element should not be used.
Protection against moisture and corrosion
Use the elements for their intended purpose – in rooms exposed to moisture, use fittings and ducts made of corrosion-resistant materials.
Store mounting accessories in dry and clean conditions.
Proper fixation and stabilization
All system components must be installed stably and in accordance with the manufacturer's instructions.
Improper fastening can lead to loose ductwork, reduced ventilation performance or structural damage.
Safety at work at height
When installing grilles or cables under the ceiling, appropriate safety safeguards such as stable ladders, scaffolding and personal protective equipment must be used.
Potential risks
Falling of elements – resulting from improper fastening of wires, fittings or grilles.
Mechanical damage – caused by improper transport or assembly.
Risk of fire – the use of unsuitable materials in high-temperature areas can lead to damage and fire hazards.
Improper air quality – installation errors can limit proper air circulation and negatively affect the comfort of users.
Maintenance and inspections
Regularly check the condition of wires, fittings, grilles and mounting accessories.
Clean the vents of dust and debris to maintain system performance.
If damage is found, replace the components with new ones in accordance with the manufacturer's recommendations.
Summary
Proper installation and operation of fittings, ducts, grilles and ventilation accessories guarantee the safety of users, system efficiency and long service life of the installation.
Compliance with the above rules minimizes the risk of failure and ensures comfortable and safe air exchange in rooms.
Ferono
Szyb Walenty 16
41-700 Ruda Śląska
Poland
606376838
info@wentec.pl