banner_wyszukiwarka(4).jpg

AHU recuperator tywent B3B EC350

The Symbol : 7901817111

Air handling unit ventilator tywent B3B EC350 • Check the details.

The Availability Of : Średnia dostępność

: 7290.00

: 7290.00

opak
Phone orde SMS: +48606376838

Shipping within : 24 hours
EAN :
5904326322837

TYWENT B3B EC 350 recuperator – Professional Ventilation with Heat and Cold Recovery

TYWENT B3B EC recuperators are modern air handling units designed for effective industrial and commercial ventilation. They provide high heat recovery in winter and cold recovery in summer, which translates into lower energy costs and comfortable indoor conditions.

The device is perfect for places such as:

  • shops and shopping malls

  • Clinics and medical offices

  • Restaurants and dining establishments

  • offices, conference rooms and open space

  • warehouses, halls and service rooms


The most important advantages of the TYWENT B3B EC 350 recuperator

🔹 Advanced counterflow heat exchanger

  • Made of cellulose, which allows for partial recovery of moisture from the exhaust air.

  • Prevents excessive drying of the air – in most cases, there is no need to use additional humidifiers.

  • No condensate drainage thanks to condensate-free design – easier installation and operation.

🔹 Automatic bypass

  • The intelligent controller allows you to switch between operating modes:

    • Heat recovery

    • Cold recovery

    • operation without an exchanger

  • Ideal for e.g. summer nights, when the air outside is cooler than indoors.

🔹 Modern design and high performance

  • Centrifugal fans with forward-curved blades, equipped with energy-saving EC motors.

  • High-quality EU4 filters effectively trap dust, dust and debris.

  • The galvanized steel housing with a micro-rubber coating guarantees durability and sound insulation.


Technical specifications of TYWENT B3B EC 350

  • Ventilation capacity: up to 550 m³/h

  • Heat exchanger: counterflow, cellulose

  • Air filters: EU4 (2-4 pcs, depending on model)

  • Fans: 2 radial ×, EC motors

  • Bypass: Automatic

  • Controller: touch, with programming modes

  • Housing: galvanised steel, soundproofed


Specifications:

  • Maximum capacity (m3/h) - 510
  • Pressure max. (Pa) - 200
  • Power (kW) - 0.22
  • Voltage (V) - 230
  • Rated Current (A) – 1.95
  • Volume [dB(A)] - 36
  • Maximum medium temperature (C) - 40
  • STEEL design
  • Mounting OTHER
  • Weight (kg) - 42
  • Inlet diameter (mm) - 200
  • Adjustable speed YES
 
Dimensions:
image

Graph:

image

DRIVER:

Multifunctional controller with touch panel included!!

image

Parameters :
Packaging Condition:
oryginalne
Status:
New
Waga produktu z opakowaniem jednostkowym:
45

Safety Information

General safety rules for fittings, ducts, grilles and mounting accessories for ventilation

Elements of ventilation systems, such as fittings, ducts, ventilation grilles and mounting accessories, have been designed to ensure proper air circulation in buildings.
Correct installation and operation are crucial for the safety of users and the performance of the entire system.

Principles of safe use and installation

Installation by qualified persons only
All installation works should be carried out by people with experience in the installation of ventilation systems and knowledge of applicable standards.

Safe mounting location

Assemble components according to the design of the ventilation system.

Avoid placing wires and grilles near heat sources, open flames, or devices that emit heat.

Avoiding mechanical damage

Do not bend, deform, or damage the ducts and fittings during assembly.

In the event of visible mechanical damage, the element should not be used.

Protection against moisture and corrosion

Use the elements for their intended purpose – in rooms exposed to moisture, use fittings and ducts made of corrosion-resistant materials.

Store mounting accessories in dry and clean conditions.

Proper fixation and stabilization

All system components must be installed stably and in accordance with the manufacturer's instructions.

Improper fastening can lead to loose ductwork, reduced ventilation performance or structural damage.

Safety at work at height
When installing grilles or cables under the ceiling, appropriate safety safeguards such as stable ladders, scaffolding and personal protective equipment must be used.

Potential risks

Falling of elements – resulting from improper fastening of wires, fittings or grilles.

Mechanical damage – caused by improper transport or assembly.

Risk of fire – the use of unsuitable materials in high-temperature areas can lead to damage and fire hazards.

Improper air quality – installation errors can limit proper air circulation and negatively affect the comfort of users.

Maintenance and inspections

Regularly check the condition of wires, fittings, grilles and mounting accessories.

Clean the vents of dust and debris to maintain system performance.

If damage is found, replace the components with new ones in accordance with the manufacturer's recommendations.

Summary

Proper installation and operation of fittings, ducts, grilles and ventilation accessories guarantee the safety of users, system efficiency and long service life of the installation.
Compliance with the above rules minimizes the risk of failure and ensures comfortable and safe air exchange in rooms.

Manufacturer details

Tywent
Orkana 1
36-020 Tyczyn
Poland

606376838
info@wentec.pl

There is currently no comments or ratings for this product.
Ask a question

Zobacz co o nas mówią klienci