Dane techniczne :

  • Wydajność Vmax m3/h - 2480
  • Maksymalne ciśnienie Pa Max - 785
  • Pobór mocy Max W - 448
  • Zasilanie V - 230
  • Maksymalne obiążenie A max - 3.3
  • Obroty RPM Max - 2490
  • Maksymalna głośność dB - 72
  • Waga kg - 48

Wymiary urządzenia :

  • A - 592 mm
  • B - 689 mm
  • C - 561 mm
  • Ød - 249 mm
  • D - 505 mm
  • E - 493,5 mm
  • F - 344 mm
  • G - 167 mm
  • H - 156 mm
  • I - 540 mm
  • J - 564 mm
  • K -  545 mm
  • L - 315 mm
image

100% Higieny

Łatwa w czyszczeniu konstrukcja, specjalnie zaprojektowany wirnik oraz drenaż w dolnej części obudowy sprawiają, że utrzymanie wentylatora w czystości jest niezwykle łatwe.

image
image

100% Wygody

Wysokowydajny wirnik oraz wibroizolatory zapewniają komfortową pracę przy relatywnie niskim poziomie hałasu, a ergonomiczne uchwyty i doskonale wyważone uchylne drzwi sprawiają, że konserwacja zajmuje minimum czasu.

100% Skuteczności

Nowoczesny wirnik, odizolowany silnik i optymalny kształt obudowy sprawiają, że wentylator zachowuje wysokie parametry pracy dla odciągów z kuchni przemysłowych i innych instalacji gastronomicznych.

image
image

Wysokotemperaturowy

Wentylator przystosowany do wyciągu medium o temperaturze do 120o C w warunkach pracy ciągłej

Parameters :
Brand:
Harmann
Kind:
kuchenny
Kod producenta:
5905036897011
Packaging Condition:
oryginalne
Status:
New
Waga produktu z opakowaniem jednostkowym:
48

Safety Information

General Safety Rules for Mechanical Fans for Building Ventilation

Mechanical fans are a key component of mechanical ventilation systems in residential, commercial and industrial buildings. Their correct installation, operation and maintenance are crucial for the safety of users, the efficiency of the system and the durability of the device.

Principles of safe use and installation

Installation by qualified personnel only
A mechanical fan should be installed by persons with appropriate electrical qualifications and experience in the installation of mechanical ventilation systems.

Correct Mounting Location

The device should be installed in accordance with the installation design and manufacturer's documentation.

Keep a safe distance from heat sources, fire, gas installations and flammable materials.

Safe electrical connection

The electrical installation must be carried out in accordance with the applicable standards and manufacturer's requirements.

The fan should be connected to a properly protected electrical circuit with proper grounding.

Any service or installation work should be performed with the power supply disconnected.

Protection against moisture and dust

Use fans for their intended purpose – wet room models must have an appropriate IP rating.

Do not install fans where there is a risk of water damage, unless they have been designed to do so.

Proper fixation of the device

The device must be mounted stably to prevent vibration, noise and possible mechanical damage.

In the case of ceiling or roof fans, additional vibration protection must be used.

Ensuring free air flow

Do not obstruct fan inlets or outlets.

Regularly check the patency of the ventilation ducts to avoid overloading the motor.

Potential risks

Electric shock – resulting from improper connection, damaged wires or lack of grounding.

Engine overheating – caused by a lack of obstruction of ventilation ducts or a blockage of the rotor.

Risk of fire – when the fan is installed near flammable materials or in unsuitable environments.

Noise and vibration – incorrect installation can lead to excessive noise and damage to the building structure.

Decrease in air quality – an incorrectly selected fan can result in insufficient air exchange, which negatively affects the health of users.

Maintenance and inspections

Regularly clean the fan of dust, dust, and other debris to maintain its performance.

Check the condition of electrical cables, connections and the rotor.

Perform periodic technical inspections in accordance with the manufacturer's recommendations.

If abnormalities are detected, such as excessive noise, vibrations, burning smell or problems with the operation of the device – disconnect the power supply and contact an authorized service center.

Summary

Mechanical fans are reliable devices that ensure proper air circulation in buildings, but they require proper installation and operation.
Compliance with the above safety rules minimizes the risk of failure, increases the efficiency of the ventilation system and extends the life of the device.

Manufacturer details

Harmann
Kokotów 703
32-002 Kokotów
Poland

606376838
info@wentec.pl

There is currently no comments or ratings for this product.
Ask a question

Zobacz co o nas mówią klienci