Single tube wall recuperator SOLO+ fi 150 remote control

The Symbol : 878534

Single tube wall recuperator SOLO+ fi 150 energy-saving remote control with hygrosco — energy-saving with hygrosco

The Availability Of : Mało

Price: 1031.00

Price: 1031.00

OptionInne rekuperatory:
opak
SMS: +48606376838

Availability and delivery

Shipping within : 24 hours
EAN :
5907660878534

Single tube wall recuperator SOLO+ fi 150 remote control

Basic technical data :

  • maximum flow - 60 m3/h

  • minimum flow - 35m3/h

  • into the room - 25m2

  • Ceramic heat exchanger!

  • has a humidity sensor

  • Power consumption - max 6.7W

  • product weight - 4kg

APPLICATION:

  • Energy efficient ventilation of heat recovery rooms
  • Air filtration
  • Maintaining proper indoor air humidity
  • Mounted in the outer wall

The recuperator works in two 60 second cycles:


I cycle
Warm, used air removed from the room
flows through the heat exchanger, transferring heat
And moisture. After 60 seconds of heating the exchanger
heat, ventilation unit switches to mode
air.
II cycle
Fresh, cool outdoor air flows through
heat exchanger. The air is moisturised and heated
by heat accumulated earlier in the exchanger.
After 60 seconds, the fan switches again
in exhaust mode and cycle repeats.

Technical details of SOLO+ recuperator

TECHNICAL DATA

  • Rated voltage -100÷230[V/50(60)Hz]
  • Power downloaded - 2,7÷6,7[W]
  • Current charged -0,020÷0,034[A]
  • Device performance -25÷450[m3/h]
  • Temperature of transported air --15....+40[°C]
  • Sound pressure level ~3m -16÷29[dB(A)]
  • Heat recovery efficiency - to85[%]
  • Safety class -IP24
  • Energy efficiency class -A

image

Recuperator equipment:

Remote control room :

Dimensions of SOLO+ 150 recuperator :

image

Edit

  • Wall mounting in the external wall - is a quick and easy installation of the ventilation unit
  • Disassembly and reassembly in another room
  • Quick and simple installation and no need to distribute the installation.

Mounting steps

1. Prepare the passage hole in the outer wall.

2. Mount the wire in the hole in such a way that its incisions are aligned with the outer and inner surface of the wall.

Styrofoam wedges included in the set can be used to facilitate installation.

Mount the ventilation duct in the wall with a minimum slope of 3 mm towards the outlet. The length of the ventilation duct can be adjusted both before and after it is placed in the wall. Remember to secure access to the outside wall

3. Install the assembled heat exchanger in and the distance ring in the air duct. In the Solo+ model, the distance ring is connected to the heat exchanger.

Schemat montażu rekuperatora ściennego SOLO+

Parameters :
Brand:
Ventika
Colour:
white
Energy efficiency class:
A
Hole diameter:
150 mm
Material:
PCV
Status:
New
Sterowanie:
na pilot
Voltage / Power:
230V

Safety Information

General safety rules for fittings, ducts, grilles and mounting accessories for ventilation

Elements of ventilation systems, such as fittings, ducts, ventilation grilles and mounting accessories, have been designed to ensure proper air circulation in buildings.
Correct installation and operation are crucial for the safety of users and the performance of the entire system.

Principles of safe use and installation

Installation by qualified persons only
All installation works should be carried out by people with experience in the installation of ventilation systems and knowledge of applicable standards.

Safe mounting location

Assemble components according to the design of the ventilation system.

Avoid placing wires and grilles near heat sources, open flames, or devices that emit heat.

Avoiding mechanical damage

Do not bend, deform, or damage the ducts and fittings during assembly.

In the event of visible mechanical damage, the element should not be used.

Protection against moisture and corrosion

Use the elements for their intended purpose – in rooms exposed to moisture, use fittings and ducts made of corrosion-resistant materials.

Store mounting accessories in dry and clean conditions.

Proper fixation and stabilization

All system components must be installed stably and in accordance with the manufacturer's instructions.

Improper fastening can lead to loose ductwork, reduced ventilation performance or structural damage.

Safety at work at height
When installing grilles or cables under the ceiling, appropriate safety safeguards such as stable ladders, scaffolding and personal protective equipment must be used.

Potential risks

Falling of elements – resulting from improper fastening of wires, fittings or grilles.

Mechanical damage – caused by improper transport or assembly.

Risk of fire – the use of unsuitable materials in high-temperature areas can lead to damage and fire hazards.

Improper air quality – installation errors can limit proper air circulation and negatively affect the comfort of users.

Maintenance and inspections

Regularly check the condition of wires, fittings, grilles and mounting accessories.

Clean the vents of dust and debris to maintain system performance.

If damage is found, replace the components with new ones in accordance with the manufacturer's recommendations.

Summary

Proper installation and operation of fittings, ducts, grilles and ventilation accessories guarantee the safety of users, system efficiency and long service life of the installation.
Compliance with the above rules minimizes the risk of failure and ensures comfortable and safe air exchange in rooms.