banner_wyszukiwarka(4).jpg

Insulated duct 50mm wool fi 160 - 10m

The Symbol : 11841323234

Insulated duct 50mm wool fi 160 - 10m It is made on the basis of Aluduct and thermal and acoustic insulation for the installation of mechanical ventilation and recuperation. An additional attribute is the vapour-tight foil placed between the internal duct and the mineral wool insulation. Thanks to it, the condensation formed by the temperature difference will not get into the wool, as a result of which it would lose its acoustic and thermal properties.

The Availability Of : Duża dostępność

: 335.00

: 335.00

Lowest price in the last 30 days:
335 335
Inne średnice:
opak
Phone orde SMS: +48606376838

Shipping within : 24 hours
EAN :
5901829005885

Duct insulated ventilation duct fi 160 with wool 50mm thick with vapour-proof foil

Ideally suited for installation in recuperation systems and non-insulated pieces of gravity and mechanical ventilation.

The diameters given in the title are internal.

It is made on the basis of Aluduct and thermal and acoustic insulation for the installation of mechanical ventilation and recuperation. An additional attribute is the vapour-tight foil placed between the internal duct and the mineral wool insulation. Thanks to it, the condensation formed by the temperature difference will not get into the wool, as a result of which it would lose its acoustic and thermal properties.

Packaging: Sections of 10 m, compressed to 1200 mm packed in a cardboard box.

Degree of flexibility (winding diameter): Relative to the specific outer diameter, i.e. approx. 0.75 x diameter in mm.

Temperature range: -20°C to +140°C

Allowed vacuum: Depending on the arrangement of the cable. In straight sections, 1/3 of the transmitted pressure can be assumed for a specific diameter. Fire classification - 2839.4/11/Z00NP and 2839.6/11/Z00NP.

Parameters :
Brand:
Wentec
Hole diameter:
160 mm
Kind:
Flexible Channel
Kod producenta:
661249
Liczba m w ofercie:
10
Material:
aluminium
Packaging Condition:
oryginalne
Size:
inny rozmiar
Status:
New
Waga produktu z opakowaniem jednostkowym:
8 (3)

Safety Information

General safety rules for fittings, ducts, grilles and mounting accessories for ventilation

Elements of ventilation systems, such as fittings, ducts, ventilation grilles and mounting accessories, have been designed to ensure proper air circulation in buildings.
Correct installation and operation are crucial for the safety of users and the performance of the entire system.

Principles of safe use and installation

Installation by qualified persons only
All installation works should be carried out by people with experience in the installation of ventilation systems and knowledge of applicable standards.

Safe mounting location

Assemble components according to the design of the ventilation system.

Avoid placing wires and grilles near heat sources, open flames, or devices that emit heat.

Avoiding mechanical damage

Do not bend, deform, or damage the ducts and fittings during assembly.

In the event of visible mechanical damage, the element should not be used.

Protection against moisture and corrosion

Use the elements for their intended purpose – in rooms exposed to moisture, use fittings and ducts made of corrosion-resistant materials.

Store mounting accessories in dry and clean conditions.

Proper fixation and stabilization

All system components must be installed stably and in accordance with the manufacturer's instructions.

Improper fastening can lead to loose ductwork, reduced ventilation performance or structural damage.

Safety at work at height
When installing grilles or cables under the ceiling, appropriate safety safeguards such as stable ladders, scaffolding and personal protective equipment must be used.

Potential risks

Falling of elements – resulting from improper fastening of wires, fittings or grilles.

Mechanical damage – caused by improper transport or assembly.

Risk of fire – the use of unsuitable materials in high-temperature areas can lead to damage and fire hazards.

Improper air quality – installation errors can limit proper air circulation and negatively affect the comfort of users.

Maintenance and inspections

Regularly check the condition of wires, fittings, grilles and mounting accessories.

Clean the vents of dust and debris to maintain system performance.

If damage is found, replace the components with new ones in accordance with the manufacturer's recommendations.

Summary

Proper installation and operation of fittings, ducts, grilles and ventilation accessories guarantee the safety of users, system efficiency and long service life of the installation.
Compliance with the above rules minimizes the risk of failure and ensures comfortable and safe air exchange in rooms.

Manufacturer details

DEC
Korczaka 37
39-300 Mielec
Poland

606376838
info@wentec.pl

There is currently no comments or ratings for this product.
Ask a question