banner_wyszukiwarka(4).jpg

Insulated flexible cable Sonodec 50 fi 200 - 10m

The Symbol : 11841325006

Insulated ventilation duct sonodec 50 fi 200 - 10m Duct insulated with wool 50mm thick, Ideally suited for installation in recuperation systems and non-insulated pieces of gravity and mechanical ventilation.

The Availability Of : Duża dostępność

: 396.00

: 396.00

Inne średnice:
opak
Phone orde SMS: +48606376838

Shipping within : 24 hours
EAN :
5901829005908

Wool insulated flexible duct 50mm thick SONODEC 50

Cable length : 10 m

Ideally suited for installation in recuperation systems and non-insulated pieces of gravity and mechanical ventilation.

The diameters given in the title are internal.

 

SONODEC 50 consists of a perforated inner duct made of aluminium laminate, thermally and acoustically insulated

wool and is equipped with an aluminium laminate outer jacket. Anti-migration barrier between the canal and wool

insulating agent increases strength and prevents diffusion of insulation particles, and also performs the following functions: improves the parameters of the

acoustic, prevents the formation of thermal bridges, leakage, pressure loss, protects the value of the R coefficient by 

moisture impact and avoids the growth of fungi in the insulation wool.

 

USE

  • Air conditioning systems
  • Air supply systems
  • Prevention of condensation in ventilation systems
  • Reduce the noise level of your equipment

TECHNICAL DESCRIPTION:

  • Product code: DS50{Ø}
  • Temperature range: -30 ⁰C to 140 ⁰C
  • Operating pressure: up to +2500 Pa
  • Max speed. flow pow.max. 30 m/s
  • Min. bending radius: 0.54 x Ø + 50mm
  • Standard diameters: 82 – 508 mm
  • Standard length: 7.5 m
CONSTRUCTION:
  • Inner Wire: Alu/poly laminate.
  • Barrier: Close. Sleeve Film
  • Glass wool: 50mm, 16kg/m³
  • Outer sheath: alu/poly laminate
  • R-value glass wool: 1.3 m² K/W
  • (ASTM C177-76)
  • Appearance: Aluminum

 

Parameters :
Brand:
Wentec
Hole diameter:
200 mm
Kind:
Flexible Channel
Kod producenta:
661249
Liczba m w ofercie:
10
Packaging Condition:
oryginalne
Size:
inny rozmiar
Status:
New
Waga produktu z opakowaniem jednostkowym:
8 (3)

Safety Information

General safety rules for fittings, ducts, grilles and mounting accessories for ventilation

Elements of ventilation systems, such as fittings, ducts, ventilation grilles and mounting accessories, have been designed to ensure proper air circulation in buildings.
Correct installation and operation are crucial for the safety of users and the performance of the entire system.

Principles of safe use and installation

Installation by qualified persons only
All installation works should be carried out by people with experience in the installation of ventilation systems and knowledge of applicable standards.

Safe mounting location

Assemble components according to the design of the ventilation system.

Avoid placing wires and grilles near heat sources, open flames, or devices that emit heat.

Avoiding mechanical damage

Do not bend, deform, or damage the ducts and fittings during assembly.

In the event of visible mechanical damage, the element should not be used.

Protection against moisture and corrosion

Use the elements for their intended purpose – in rooms exposed to moisture, use fittings and ducts made of corrosion-resistant materials.

Store mounting accessories in dry and clean conditions.

Proper fixation and stabilization

All system components must be installed stably and in accordance with the manufacturer's instructions.

Improper fastening can lead to loose ductwork, reduced ventilation performance or structural damage.

Safety at work at height
When installing grilles or cables under the ceiling, appropriate safety safeguards such as stable ladders, scaffolding and personal protective equipment must be used.

Potential risks

Falling of elements – resulting from improper fastening of wires, fittings or grilles.

Mechanical damage – caused by improper transport or assembly.

Risk of fire – the use of unsuitable materials in high-temperature areas can lead to damage and fire hazards.

Improper air quality – installation errors can limit proper air circulation and negatively affect the comfort of users.

Maintenance and inspections

Regularly check the condition of wires, fittings, grilles and mounting accessories.

Clean the vents of dust and debris to maintain system performance.

If damage is found, replace the components with new ones in accordance with the manufacturer's recommendations.

Summary

Proper installation and operation of fittings, ducts, grilles and ventilation accessories guarantee the safety of users, system efficiency and long service life of the installation.
Compliance with the above rules minimizes the risk of failure and ensures comfortable and safe air exchange in rooms.

Manufacturer details

DEC
Korczaka 37
39-300 Mielec
Poland

606376838
info@wentec.pl

Reviews are not verified
  • Klimi (2023-08-31)
    The Whole Thing
    (1)
    The Functionality Of The
    (1)
    Price
    (1)
    Super jakość !!! polecam
Ask a question

Zobacz co o nas mówią klienci